Over Crank

Over crank

Fuel · Alarm

The red over-crank icon means the engine did not start. Manual 100515 shuts the generator down so it does not damage the starter. In AUTO the printed cycle is 9 seconds crank, 10 seconds off, 5 cycles, then a 120 second lockout. Pressing OFF does not skip that lockout. You wait until the timer reaches zero before another start. The manual says to check that in-line fuel shutoff valves are open, and that a weak battery can keep the starter from reaching starting speed. A fuel-pressure (manometer) check is assigned to a dealer or installer.

Seen on: Champion home standby generators with the aXis controller covered by operator manual 100515. These are icon faults, not four-digit numeric codes.

Likely causes

  • Fuel shutoff closed, or not enough fuel pressure.
  • Battery too weak to crank fast enough. The manual points at the battery-charger 'no charge' icon.

Checks an owner can do

  1. Put in-line fuel valves in the ON/OPEN position.
  2. Check the battery-charger icon. If it shows no charge, test the battery the way the battery maker describes.
  3. Wait out the 120 second lockout even if you already pressed OFF.

When to call a pro

A manometer fuel-pressure test, and any over-crank that remains with the valves open and a good battery, goes to an authorized Champion dealer or installer.

Source

Champion Power Equipment operator's manual 100515 (English), aXis controller fault icons for the home standby generator.

Wording follows that document. Firmware can change a threshold. If this page and the manual shipped with your unit disagree, follow the manual.

What fixed mine

No approved reports for this code yet. Send one. It stays in the review queue until it is approved.