1200

Overspeed, prolonged

Engine · Alarm

Alarm 1200 is prolonged overspeed. On a 60 Hz set the table describes frequency over the specified limit (72 Hz) for 3 seconds. On a 50 Hz set the same row uses 60 Hz. The listed cause is the stepper motor or mixer body.

Seen on: Air-cooled home standby generators with an Evolution 1.0 or 2.0 controller.

Likely causes

  • Stepper motor or mixer (throttle) unplugged, jammed, or otherwise holding engine speed up.
  • This is a speed alarm. It is not e-code 1300.

Checks an owner can do

  1. Leave the generator shut down. Do not keep clearing 1200 and letting it restart.
  2. A look for an obvious disconnected stepper plug is reasonable only with the battery disconnected and no attempt to run the set.

When to call a pro

The manual sends this alarm to the stepper-motor and mixer tests. Fuel-mixer work is technician work, and an overspeed can damage the alternator.

Source

Generac Diagnostic Repair Manual 10000041488 (Evolution 1.0/2.0 air-cooled). E-code rows below match that manual's alarm table as published by Home Generators for Sale and the manual text extracted from document 10000041488.

Wording follows that document. Firmware can change a threshold. If this page and the manual shipped with your unit disagree, follow the manual.